Modular Office Buildings
Twin & triple modular office buildings
Tailor-made modular buildings for Versatile Space Requirements
Discover the versatility and functionality of our modular container units with CHV Container. Whether you need expanded office space or want to create creative project environments, our double and triple container units offer flexible and immediately usable work environments.
Twin modular office building: Compact and expandable office space
Our twin modular office building combines two 20-ft office containers into a spacious 30 m² area. Four large windows ensure a bright and inviting atmosphere. High-quality electrical and lighting installations allow for immediate use. The unit is designed to be flexibly adapted to different usage concepts via removable interior walls.
Triple modular building: Extensive space for your projects
The triple modular building consists of three 20-ft office containers placed side by side, providing a total area of 45 m². Six windows flood the room with natural light, creating an open and productive work atmosphere. This basic configuration offers expansion options and adaptability according to your specific requirements.
Expandability and individual configuration:
- Stackability: Our containers can be safely stacked up to three levels high, ideal for constructing multi-story container systems.
- Access solutions: Choose between external stairs or an integrated staircase container for access to higher levels.
- Flexible layout: Integrate containers for WC and sanitary facilities or use corridor containers to create efficient traffic systems within the complex.
- Individual design: Customize each unit to your needs, from the arrangement of doors and windows to the selection of interior walls and specific expansion modules.
With a container unit from CHV Container, you are investing in a solution that offers flexibility, adaptability, and expandability, growing with your company’s needs. Our container systems represent a long-term investment characterized by modifiability and scalability.
Contact CHV Container today to learn more about our double and triple container units and how we can help you effectively meet your space requirements with tailor-made solutions.
Need a temporary solution instead?
twin and triple modular office buildings for rent
How CHV Office Containers Are Built
CHV office containers combine a welded steel frame with insulated floor, roof and wall elements, factory-installed electrical equipment and configurable windows, doors and internal layouts. The sections below describe the typical construction; the final specification is confirmed for the selected model and intended use. Explore office-container equipment and finishes >
Structural Frame & Modular Design
The load-bearing structure comprises a welded floor frame, roof frame and corner posts made from 3 mm galvanized, coated steel profiles. The modular design allows containers to be positioned individually, arranged side by side or combined into larger facilities. Wall openings and internal partitions can be planned around the required layout. Stacked solutions are possible where the project-specific structural design, foundations and approvals permit them.
Roof Construction
The flat roof uses a welded steel frame and a galvanized sheet-steel outer skin with sealed double seams. Mineral-wool or rigid-foam insulation and an internal ceiling lining complete the build-up. The insulation and lining are specified for the model, intended use and required thermal performance.
Floor Construction
A galvanized, coated steel floor frame with forklift pockets provides the structural base. The standard build-up includes 100 mm non-combustible mineral-wool insulation, an underfloor sheet layer, a 20 mm cement-bonded board and durable, low-smoke, flame-retardant 1.5 mm homogeneous PVC flooring. XPS insulation and alternative floor finishes are available for suitable applications.
Insulated Wall System
External wall elements combine coated galvanized sheet steel, mineral-wool insulation and a durable white internal lining. The same modular principle can be used for partitions, allowing practical layouts with consistent surface finishes. Thermal and acoustic performance depends on the selected wall build-up and openings.
Windows & Glazing
Standard office-container windows use insulating glazing with tilt-and-turn hardware and external roller shutters. Depending on the model and application, options include sliding windows, service hatches, fixed glazing and larger display or showroom glazing. Number, position and dimensions are coordinated with the layout and structural requirements.
Doors & Access
Single-leaf steel exterior doors with secure locking are the usual standard. Options include glazed door leaves, double-leaf doors, alternative entrance positions and interior doors. Wider or step-free access, ramps and platform solutions are planned as project-specific access systems rather than assumed as standard.
Electrical Installation
Factory-installed electrical equipment is adapted to the selected model. Full-size office-container models include a 400 V / 32 A / 5-pin CEE inlet and outlet, a distribution board with RCD protection, separately protected circuits, lighting, switches and sockets. Final equipment and the applicable electrical standards and conformity requirements are confirmed for the project and installation location.
Heating, Cooling & Ventilation
Heating provision depends on the model and configuration. Standard heater quantities for the full-size models are shown in the comparison table; heating remains optional for the 5-ft cabin. Additional electric wall convectors, mechanical extract ventilation and compact or split air-conditioning systems can be specified according to the intended occupancy and operating conditions. Capacity and placement are defined for the container size, glazing, insulation and site conditions.
Quality Control & Project-Specific Requirements
CHV office containers are produced and checked against the agreed specification. Structural design, fire-performance requirements, electrical documentation and any application-specific approvals or certificates are defined for the selected model, configuration and installation site.
Standard Equipment by Office Container Model
![]() |
|
![]() |
![]() |
![]() |
|
|---|---|---|---|---|---|
| 5 ft | 1.45 m | 10 ft | 3 m | 16 ft | 4.8 m | 20 ft | 6 m | 24 ft | 7.3 m | 30 ft | 9 m |
| Steel entrance door, 800 × 2,000 mm, with security lock | |||||
| 1 configuration-specific window | 1 tilt-and-turn window with roller shutter | 2 tilt-and-turn windows with roller shutters | 3 tilt-and-turn windows with roller shutters | ||
| 1 × 60 W round light | 1 × 36 W light bar | 2 × 36 W light bars | 3 × 36 W light bars | ||
| Electrical installation | 400 V / 32 A / 5-pin CEE inlet and outlet | ||||
| 1 light switch • 1 double socket • 1 distribution board | 2 double sockets | ||||
| Heating optional | 1 × 2 kW heater | 2 × 2 kW heaters |
|||
![]() |
![]() |
||
|---|---|---|---|
| Two-module office unit | Three-module office unit | ||
| 6 m × 4.8 m | approx. 30 m² | 6 m × 7.3 m | approx. 45 m² | ||
| 1 entrance door, 800 × 2,000 mm |
|||
| 4 tilt-and-turn windows with roller shutters | 6 tilt-and-turn windows with roller shutters | ||
| 4 × 36 W light bars | 6 × 36 W light bars | ||
| 2 double sockets | 3 double sockets | ||
| 1 light switch | |||
| 2 distribution boards | 3 distribution boards | ||
| 2 × 400 V / 32 A / 5-pin CEE inlets and outlets | 3 × 400 V / 32 A / 5-pin CEE inlets and outlets | ||
| 2 × 2 kW heaters | 3 × 2 kW heaters | ||
Office-Container Models and Modular Units: Technical Data
| MODEL | FLOOR PLAN | DIMENSIONS | APPROX. AREA | |
|---|---|---|---|---|
| CHV-060 | 5 ft | 1.45 m | ![]() |
1,450 × 1,300 × 2,591 mm | 1.9 m² |
| CHV-150 | 10 ft | 3 m | ![]() |
2,991 × 2,438 × 2,791 mm | 7 m² |
| CHV-300.48 | 16 ft | 4.8 m | ![]() |
4,886 × 2,438 × 2,791 mm | 12 m² |
| CHV-300 | 20 ft | 6 m | ![]() |
6,058 × 2,438 × 2,791 mm | 15 m² |
| CHV-300.73 | 24 ft | 7.3 m | ![]() |
7,334 × 2,438 × 2,791 mm | 18 m² |
| CHV-300.90 | 30 ft | 9 m | ![]() |
9,120 × 2,438 × 2,791 mm | 22 m² |
| CHV-300DA | 20 ft × 16 ft 6 m × 4.8 m |
![]() |
6,058 × 4,886 × 2,791 mm | 30 m² |
| CHV-300 Triple | 20 ft × 24 ft 6 m × 7.3 m |
![]() |
6,058 × 7,334 × 2,791 mm | 45 m² |