Modular Office Buildings
Twin and triple modular office buildings
Compact office buildings designed to grow with your requirements
CHV twin and triple modular office buildings turn proven 20-ft office modules into larger, open-plan workspaces. The two standard configurations provide approximately 30 m² or 45 m² and are suitable for site offices, project teams, operational facilities and longer-term business extensions.
The displayed prices cover the complete material package for the selected building, including the components required to join, seal and finish the modules. Transport, crane placement, foundations, on-site assembly and final site connections are planned and priced separately.
Twin modular office building
Approximately 30 m² from two joined office modules
The twin configuration combines two 20-ft office modules to create an open workspace measuring approximately 6.0 × 4.8 m. Its standard specification includes one entrance door, four insulated tilt-and-turn windows with roller shutters and the corresponding lighting, electrical distribution, sockets, CEE connections and heating equipment.
The configuration provides a practical starting point for team offices, meeting and project rooms or a compact operational building. Door and window positions and the internal arrangement can be coordinated around the intended use.
Triple modular office building
Approximately 45 m² for larger teams and flexible layouts
Three joined 20-ft office modules provide approximately 45 m² of floor space in a building measuring around 6.0 × 7.3 m. Six insulated tilt-and-turn windows with roller shutters bring daylight into the open interior, while the standard electrical and heating equipment is scaled to the three-module configuration.
The additional width supports larger team areas, combined work and meeting zones or more detailed room layouts. Internal partitions, alternative entrances and further equipment can be incorporated when the final use is defined.
Included building components
The material package includes the joining profiles, roof detailing, weather sealing, electrical interconnection and internal joint finishes required for the selected twin or triple building. This keeps the building specification coordinated while allowing the installation itself to be planned for the actual site.
Transport, delivery, crane work, foundations, on-site assembly and utility connections are not included in the displayed product price. CHV can coordinate these services as part of the complete project scope.
From compact configurations to larger modular facilities
Twin and triple buildings are convenient standard starting points, not the limit of the system. Four-, five- and larger-module office facilities can be planned just as readily, with corridor modules, sanitary facilities, stairs and platforms, and multi-storey access solutions added where the project requires them.
For larger or more complex facilities, CHV develops the room schedule, module layout, access, services and installation sequence around the intended use and site conditions.
Need a temporary solution instead?
Twin and triple modular office buildings for rent
How CHV Office Containers Are Built
CHV office containers combine a welded steel frame with insulated floor, roof and wall elements, factory-installed electrical equipment and configurable windows, doors and internal layouts. The sections below describe the typical construction; the final specification is confirmed for the selected model and intended use. Explore office-container equipment and finishes >
Structural Frame & Modular Design
The load-bearing structure comprises a welded floor frame, roof frame and corner posts made from 3 mm galvanized, coated steel profiles. The modular design allows containers to be positioned individually, arranged side by side or combined into larger facilities. Wall openings and internal partitions can be planned around the required layout. Stacked solutions are possible where the project-specific structural design, foundations and approvals permit them.
Roof Construction
The flat roof uses a welded steel frame and a galvanized sheet-steel outer skin with sealed double seams. Mineral-wool or rigid-foam insulation and an internal ceiling lining complete the build-up. The insulation and lining are specified for the model, intended use and required thermal performance.
Floor Construction
A galvanized, coated steel floor frame with forklift pockets provides the structural base. The standard build-up includes 100 mm non-combustible mineral-wool insulation, an underfloor sheet layer, a 20 mm cement-bonded board and durable, low-smoke, flame-retardant 1.5 mm homogeneous PVC flooring. XPS insulation and alternative floor finishes are available for suitable applications.
Insulated Wall System
External wall elements combine coated galvanized sheet steel, mineral-wool insulation and a durable white internal lining. The same modular principle can be used for partitions, allowing practical layouts with consistent surface finishes. Thermal and acoustic performance depends on the selected wall build-up and openings.
Windows & Glazing
Standard office-container windows use insulating glazing with tilt-and-turn hardware and external roller shutters. Depending on the model and application, options include sliding windows, service hatches, fixed glazing and larger display or showroom glazing. Number, position and dimensions are coordinated with the layout and structural requirements.
Doors & Access
Single-leaf steel exterior doors with secure locking are the usual standard. Options include glazed door leaves, double-leaf doors, alternative entrance positions and interior doors. Wider or step-free access, ramps and platform solutions are planned as project-specific access systems rather than assumed as standard.
Electrical Installation
Factory-installed electrical equipment is adapted to the selected model. Full-size office-container models include a 400 V / 32 A / 5-pin CEE inlet and outlet, a distribution board with RCD protection, separately protected circuits, lighting, switches and sockets. Final equipment and the applicable electrical standards and conformity requirements are confirmed for the project and installation location.
Heating, Cooling & Ventilation
Heating provision depends on the model and configuration. Standard heater quantities for the full-size models are shown in the comparison table; heating remains optional for the 5-ft cabin. Additional electric wall convectors, mechanical extract ventilation and compact or split air-conditioning systems can be specified according to the intended occupancy and operating conditions. Capacity and placement are defined for the container size, glazing, insulation and site conditions.
Quality Control & Project-Specific Requirements
CHV office containers are produced and checked against the agreed specification. Structural design, fire-performance requirements, electrical documentation and any application-specific approvals or certificates are defined for the selected model, configuration and installation site.
Standard Equipment by Office Container Model
| | | | | | |
|---|---|---|---|---|---|
| 5 ft | 1.45 m | 10 ft | 3 m | 16 ft | 4.8 m | 20 ft | 6 m | 24 ft | 7.3 m | 30 ft | 9 m |
| Steel entrance door, 800 × 2,000 mm, with security lock | |||||
| 1 configuration-specific window | 1 tilt-and-turn window with roller shutter | 2 tilt-and-turn windows with roller shutters | 3 tilt-and-turn windows with roller shutters | ||
| 1 × 60 W round light | 1 × 36 W light bar | 2 × 36 W light bars | 3 × 36 W light bars | ||
| Electrical installation | 400 V / 32 A / 5-pin CEE inlet and outlet | ||||
| 1 light switch • 1 double socket • 1 distribution board | 2 double sockets | ||||
| Heating optional | 1 × 2 kW heater | 2 × 2 kW heaters | |||
| | | ||
|---|---|---|---|
| Two-module office unit | Three-module office unit | ||
| 6 m × 4.8 m | approx. 30 m² | 6 m × 7.3 m | approx. 45 m² | ||
| 1 entrance door, 800 × 2,000 mm | |||
| 4 tilt-and-turn windows with roller shutters | 6 tilt-and-turn windows with roller shutters | ||
| 4 × 36 W light bars | 6 × 36 W light bars | ||
| 2 double sockets | 3 double sockets | ||
| 1 light switch | |||
| 2 distribution boards | 3 distribution boards | ||
| 2 × 400 V / 32 A / 5-pin CEE inlets and outlets | 3 × 400 V / 32 A / 5-pin CEE inlets and outlets | ||
| 2 × 2 kW heaters | 3 × 2 kW heaters | ||
Office-Container Models and Modular Units: Technical Data
| MODEL | FLOOR PLAN | DIMENSIONS | APPROX. AREA | |
|---|---|---|---|---|
| CHV-060 | 5 ft | 1.45 m | 1,450 × 1,300 × 2,591 mm | 1.9 m² | |
| CHV-150 | 10 ft | 3 m | 2,991 × 2,438 × 2,791 mm | 7 m² | |
| CHV-300.48 | 16 ft | 4.8 m | 4,886 × 2,438 × 2,791 mm | 12 m² | |
| CHV-300 | 20 ft | 6 m | 6,058 × 2,438 × 2,791 mm | 15 m² | |
| CHV-300.73 | 24 ft | 7.3 m | 7,334 × 2,438 × 2,791 mm | 18 m² | |
| CHV-300.90 | 30 ft | 9 m | 9,120 × 2,438 × 2,791 mm | 22 m² | |
| CHV-300DA | 20 ft × 16 ft 6 m × 4.8 m | 6,058 × 4,886 × 2,791 mm | 30 m² | |
| CHV-300 Triple | 20 ft × 24 ft 6 m × 7.3 m | 6,058 × 7,334 × 2,791 mm | 45 m² |